ZShooter Air Harnesses & Connections#
Scope: facility air, enclosure feeds, and ZFront actuators if pneumatic mechanisms are selected. Related operations: environmental services. Diagram: hardware composition.
Assembly boundaries#
ZFront air manifold and pressure sensing
ZFront enclosure and mechanisms
ZImager enclosure feed
ZSpec VIS enclosure feed
Air connections#
From |
To |
Service |
Detail |
|---|---|---|---|
RNAS facility air |
ZFront manifold |
Supply |
Regulation, treatment, and isolation open |
ZFront manifold |
ZFront enclosure |
Positive pressure |
Local route open |
ZFront manifold |
ZImager enclosure |
Positive pressure, with dryer |
Dryer placement and module connection open |
ZFront manifold |
ZSpec VIS enclosure |
Positive pressure, with dryer |
Dryer placement and module connection open |
ZFront manifold |
Point-source, calibration insertion, ZImage/ZSpec selector actuators |
Pneumatic supply, if selected |
Valve ports, exhaust, and actuator connections open |
Electrical connections#
From |
To |
Function |
|---|---|---|
ZFront EBox |
Manifold |
Power and pressure sensing |
Mechanism controller |
Valves and position sensors, if fitted |
Mechanism actuation and position |
Local wiring is in the ZFront harness. Tube assemblies, fittings, ports, and removal connections will be linked through the manifold and harness drawings.
Team notes: The actuator choice determines the valve arrangement and loss-of-air position. Enclosure pressure/flow requirements, treatment, and isolation of removed modules remain to be assigned.